News Center
SF6-Air Collection Schneider

SF6-Air Collection Schneider

2021-3-18MCset is Schneider Electric's AIS – Air Insulated Switchgear (indoor metal-enclosed device) intended for the MV section of HV/MV substations and high power MV/MV substations up to 24kV. Main component of MCset

[email protected]
News Detail
  • SF6 properties, and use in MV and HV - Schneider

    2019-1-11Cahier Technique Schneider Electric nO. 188 / p.3 SF6 properties, and use in MV and HV switchgear Contents 1 Introduction 1.1 A brief history of use of SF6 p.4 1.2 SF6 manufacture p.5 1.3 Other uses of SF6 p.5 2 Physical and chemical properties of SF6 2.1 Physical properties p.6 2.2 Chemical properties p.8

    Get Price
  • Schneider Electric : Why transition to SF6-free pure air

    Pure air is the ultimate replacement of the greenhouse gas. It makes the concerns around GWP obsolete, as it has none. But more than that, its environmental safety is fully transparent. #2: Pure Air Requires No Recycling. The pure air we breathe every day requires no recycling, naturally. The same cannot be said of SF 6 or other man

    Get Price
  • Schneider Electric’s SF6-Free MV Switchgear Using Pure

    Schneider Electric’s innovative new SF6-free switchgear technology using pure air has been nominated for the world’s most important industrial prize, the HERMES Award.The new medium voltage switchgear, which uses pure air instead of the industry-standard SF6 greenhouse gas, is among the three contenders for this

    Get Price
  • Medium voltage switchgear - Schneider Electric

    2019-2-21 SF6 is used in electrical equipment because of its dielectric strength, excellent insulating properties and its arc-suppression capabilities. It insulates 2.5 times better than air (N2), so it allows very compact design Its quenching properties are 100 times better than air (N2) and has better heat dissipation than in air

    Get Price
  • MCset - Air Insulated Switchgear with SF6 CB

    2021-3-18MCset is Schneider Electric‘s AIS – Air Insulated Switchgear (indoor metal-enclosed device) intended for the MV section of HV/MV substations and high power MV/MV substations up to 24kV. Main component of MCset

    Get Price
  • Circuit breakers SF 1 to 40.5 kV SF6 - Schneider

    2019-5-27SF6 is non-toxic. a non-inflammable gas SF6 is an inert gas and does not sustain combustion. a very stable gas The high stability of SF6 gas is due to the 6 covalent bonds of its molecule. an insulating gas The dielectric strength of SF6 is superior to that of most known media, reaching 5 times that of air at a pressure of

    Get Price
  • Cahier technique no 198 - download.schneider

    2021-1-26SF6 and vacuum are the two most modern breaking techniques in the fields of Medium Voltage (from 1 to 52 kV) and High Voltage ( 72.5 kV). They appeared in the 1960’s and rapidly developed as of the 1970’s. Today they have replaced the former air and oil breaking techniques (see fig. 1 ). Fig.1: evolution of

    Get Price
  • instructions for use - Schneider Electric

    2019-2-8drawn up by Schneider Electric. safety rules CAUTION All the operations described below must be performed in compliance with applicable safety standards, under the responsibility of a competent authority. WARNING Thecontractormustbecertified and authorised to manipulate and perform work on

    Get Price
  • Schneider Electric Wins Industrial Energy Efficiency

    Schneider Electric, the leader in digital transformation of energy management and automation, has won the Industrial Energy Efficiency Award category Energy Economy for its new SM AirSeT

    Get Price
  • Medium-voltage product offer - Schneider Electric

    2020-3-31CBGS-0 SF6 circuit breaker switchgear Ratings/features • Up to 38 kV, 2,000 A, 31.5 kA, and 150 kV BIL • Compact design 24” W for mains/feeders and 48” W for tie • Fixed vacuum or SF6 circuit breaker • Solid insulated and shielded bus bar system • Internal arc tested 31.5 kA/1 s per IEC 62271-200

edge-iconRelated News
toTop
Click avatar to contact us