Ni-CNT Chemical Sensor for SF6 DecompositionCited by: 5Publish Year: 2018Author: Yingang Gui, Xiaoxing Zhang, Peigeng Lv, Shan Wang, Chao Tang, Qu ZhouLocation: 8600 Rockville Pike, Bethesda, MDsf6-gas decomposition components detection is a key technology to evaluate and diagnose the insulation status of sf 6-insulated equipment online, especially when insulation defects-induced discharge occurs in equipment.In order to detect the type and concentration of sf6-gas decomposition components, a Ni-modified carbon
[email protected]Fast and reliable SF6 detection Equipped with non-dispersive infrared technology (NDIR), the SF6 transmitter detects sulfur hexafluoride quickly and reliably even in the ppm range in ambient air. The optical measuring technology works according to a physical measuring principle – without chemical reactions or wearing parts.
Get PriceNanomaterials Based Gas Sensors for SF6 Decomposition Components Detection 10 [33] Ding W, Hayashi R, Ochi K, et al. Analysis of PD-generated SF 6 decomposition gases adsorbed on carbon nanotubes.
Get PriceThe component detection system adopted the SHIMADZU QP2010Ultra gas chromatography‐mass spectrometry (GC/MS) device for the quantitative analysis of the SF 6 decomposition components. The instrument adopted helium gas with a purity of 99.9995% as carrier gas; the chromatographic column box temperature
Get PriceAs one of the key characteristic components that result from sulfur hexafluoride (SF6) decomposition in SF6 gas-insulated equipment, hydrogen sulfide (H2S) can reflect the severity of the internal
Get Price2017-8-27further research trend on CNTs in the detection of SF 6 decomposition components is also put forward. Keywords: CNTs, SF 6, Decomposition components, Gas response Introduction Sulfur hexafluoride (SF 6) gas is widely applied as electrical insulator as well as arc-quenching medium in gas-insulated switchgear
Get PriceSF6 gas Mixtures Decomposition for subway. PD can cause decomposition of sf 6 gas, resulting in the production of various low-fluorine sulfides, such as SF 4, SF 3, SF 2, and S 2 F 10. 1 – 3 Because of the presence of trace impurities, such as H 2 O and O 2, in the equipment, these low-fluorine sulfides generate many more stable decomposition
Get PriceFixed Gas Detection Our fixed gas detectors monitor your production locations, warehouses and workplaces and warns you against imminent gas hazards and flames. In addition to a uniquely wide range of sensors, stationary gas transmitters and technical components we offer expert planning, maintenance, service and